VTK6222-PK, External power isolation kit

In stock
SKU:
VTK6222-PK, External power isolation kit
Brand: Nexcom

External Attachable Railway Power Isolation Kit for nROK 6222


Downloads:

Enquire Now
Enquire about this product
We build to order
Input Voltage VTK-6222-APK: 24VDCVTK-6222-FPK: 110VDC
Input Connector M12 (5-pin)
Output Voltage 24VDC
Output Connector M12 (5-pin)
Rated Power 150W
Dimensions 145 x 218 x 49 (W x D x H) (mm)
Weight 1.7kg
Environment Operating temperatures
- EN 50155, class OT4 -40 ~ 70°C, 85°C for 10 minutes
Storage temperatures: -40°C~80°CRelative humidity: 90% (non-condensing)Vibration (random)
- [email protected]~500 Hz
Vibration
- Operating: MIL-STD-810G, Method 514.6, Category 4, common carrier US highway truck vibration exposure
- Storage: MIL-STD-810G, Method 514.6, Category 24, minimum integrity test
Shock
- Operating: MIL-STD-810G, Method 516.6, Procedure I, functional shock=40g
- Non-operating: MIL-STD-810G, Method 516.6, Procedure V, crash hazard shock test=75g
Standards/Certifications with nROK6222 CEFCC Class AEN 50155:2017
- Ambient temperature EN 50155, class OT4 (-40 ~ 70°C, 85°C for 10 minutes)
- Shock and vibration IEC 61373 class B
- Interruptions of voltage supply class S1
- Supply change over class C1, C2
- EMC EN 50121-3-2:2016